Mouse sRANKL(Soluble Receptor Activator of Nuclear factor-kB Ligand) Microsample ELISA Kit

Mouse sRANKL(Soluble Receptor Activator of Nuclear factor-kB Ligand) Microsample ELISA Kit

AO-06-ELK2648MS-96T

Mouse sRANKL(Soluble Receptor Activator of Nuclear factor-kB Ligand) Microsample ELISA Kit 96T

check In Stock
Hurry! only 10 items left in stock.
€489.00
Tax excluded
Quantity

Product Overview

Cat.No ELK2648MS
Product Name Mouse sRANKL(Soluble Receptor Activator of Nuclear factor-kB Ligand) Microsample ELISA Kit
Reactivity Mouse
Alternative Names CD254; TNFSF11; ODF; OPGL; TRANCE; HRANKL2; SOdf; Tumor Necrosis Factor(ligand)superfamily Member 11; TNF-related activation-induced cytokine; RANkL; Receptor Activator Of Nuclear Factor Kappa B Ligand
Assay Type Sandwich
Sensitivity 5.7 pg/mL
Standard 1000 pg/mL
Detection Range 15.63-1000 pg/mL
Sample Type serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length 3.5h
Research Area Signal transduction;Metabolic pathway;Apoptosis;Tumor immunity;Bone metabolism;
Test Principle The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse sRANKL. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse sRANKL. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse sRANKL, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse sRANKL in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard Curve

ELK2648MS-b-1.jpg
: AO-06-ELK2648MS-96T
: 10 Items
Hurry! only 10 items left in stock.

Use collapsible tabs for more detailed information that will help customers make a purchasing decision.

Ex: Shipping and return policies, size guides, and other common questions.

  • Paste the label on a flat surface on the package
  • Make sure that both 1D and 2D barcodes are clearly visible
  • Ensure that the label is smooth and isn’t creased or wrinkled
  • Check for any tears, dents, holes or scratches
  • Pack your product tightly, with the right size packaging
  • Ensure both barcodes are on a flat surface of the package