SWE Rapid High Resolution Running Buffer (Powder)

SWE Rapid High Resolution Running Buffer (Powder)

Servicebio
AO-03-G2081-15

A new generation of electrophoretic buffer to experience better WB.

check In Stock
Hurry! only 10 items left in stock.
€149.00
Tax excluded
Quantity

Product Information

Product Name

Cat. No.

Spec.

SWE Rapid High Resolution Running Buffer (Powder)

AO-03-G2081-1L

1 L

AO-03-G2081-15

1 L, 15 bags

Product Description/Introduction

The SWE Rapid High Resolution Running Bufferr (powder) is optimal to Tris-Glycine electrophoresis buffer for SDS-PAGE gel electrophoresis in Tris-Glycine. Compared with the traditional Tris-glycine running buffer, this product can be used for electrophoresis without adjusting the voltage according to the separation gel and the stacking gel, and it can be used for the whole process of electrophoresis at a constant voltage of 200-250 V. It takes about 30 min to complete the electrophoresis, which saves time and is more effective for the separation of small molecules. It can separate the 10 kDa and the 15 kDa bands in the prestained protein marker and clearly visible (gel concentration above 8%) to achieve rapid and efficient isolation of 

proteins.

Storage and Shipping Conditions

Ship and store at room temperature. Valid for 24 months.

Assay Protocol/Procedures

1. Each bag of electrophoresis buffer (powder) is dissolved in 1000 mL of purified water, and can be used after fully dissolved.

2. Selection of different protein gel concentrations for different protein molecular weights, refer to the table below:

SDS-PAGE Separation Gel Concentration

Optimum Separation Range (kDa)

(SWE Rapid High Resolution Running Buffer)

6%

15-300

8%

10-250

10%

5-150

12%

3-100

15%

<60

3. Constant voltage electrophoresis, 200-250 V, Refer to the following table for electrophoresis time:

Comparison Table of Electrophoresis Voltage and Electrophoresis Time

Voltage(V)

Estimated Electrophoresis Time(min)

200

35

220

30

250

25

Note

4. It is recommended to use the working solution as soon as possible after preparation.

5. This product is suitable for conventional Tris-HCl system SDS-PAGE gels, such as our products  G2003, G2037, G2041, G2042,G2043,G2044,G2045,G2060,G2061,G2062, G2063,G2064.

6. High voltage electrophoresis is easy to produce high heat. Please select the appropriate voltage for electrophoresis according to the ambient temperature.

7. The running solution can be reused for 2-3 times, more reuse is not recommended.

8. For your safty and health, please wear safety glasses, gloves, or protective clothing.

 

For Research Use Only!

: AO-03-G2081-15
: 10 Items
Hurry! only 10 items left in stock.

Use collapsible tabs for more detailed information that will help customers make a purchasing decision.

Ex: Shipping and return policies, size guides, and other common questions.

  • Paste the label on a flat surface on the package
  • Make sure that both 1D and 2D barcodes are clearly visible
  • Ensure that the label is smooth and isn’t creased or wrinkled
  • Check for any tears, dents, holes or scratches
  • Pack your product tightly, with the right size packaging
  • Ensure both barcodes are on a flat surface of the package