Tissue Homogenizer Low Temperature (-50℃, Freezing Chamber)

Servicebio
AO-03-SWE-FP
check En Stock
Hurry! only 3 items left in stock.
9 990,00 €
HT
Quantité

Product Introduction
SWE-FP is a newly upgraded low-temperature homogenizer, which can reach a temperature as low as -50℃ in the chamber and also equipped with a freezing chamber.Adopt high-speed reciprocating motion of the vertical shaking system, the frozen sample in the grinding tube collides with the grinding bead, and the resulting grinding shear force and impact force completely break down the tissue. Up to 192 samples can be processed simultaneously in one minute, making it a dedicated device that meets the requirements of rapid processing of multi-sample.

Product Features

1. Slider drive, no wear shaft, noise stability and durability;
2. Equiped with low temperature freezing chamber. It can meet the needs of sample storage, electrophoresis, membrane transfer and other low-temperature experiments
3. Imported compressor,lowest cooling temperature of -50℃,low temperature grinding throughout the process,reducing degradation of proteins and RNA.
4. Up to 192 samples can be processed simultaneously in 1 minute (24 samples can be processed with standard),efficiently and effectively completing sample grinding with high throughput.
5. Multiple adapters to choose.

Technical Parameters


1. Dimensions:Length 650mm,Width 420mm,Height 430mm
2. Weight:54 kg
3. Screen size:5 inches
4. Temperature:-50℃
5. Temperature control precision:±1℃
6. Working time:Runtime0-9999s,pausetime0-999s,andruntimes1-99times

Parameters Comparison

Cat. No.

SWE-FP

Operating mode

The vertical shaking system moves back and forth at high speed.

Temperature

-50℃

Temperature control precision

±1℃

Standard spec.

24*2 mL

Maximum sample volume

192 pcs

Adapter specification

24x0.5mL.24x2mL.48x2mL.
32x2mL.60x2mL.96x2mL.
12x5mL.10x10mL.4x30mL(steel can).
6x5mL(steel can).8x15mL(steel can)
2x50mL(steel can).96x2mL(2pcs 96-deep well plate)

Freezing chamber

YES

Adapter fixing method

Nut

Working time

0-99min99s

Dimensions

650*420*430mm

Screen size

5 inches

Emergency stop button

YES

Electromagnetic safety lock

Screen click control with automatic power-off unlocking. the cover cannot be opened during operation until the grinding program ends, fully protected.

Maximum feeding size

No requirements, adjustable according to the adapter.

Weight

54kg

Power parameters

200-240VAC,50-60 Hz,500 W

Cooling method

Compressor cooling

Transport screws

Yes (2 at the bottom)

Advantages

Lower cooling temperature can reach -50℃. low temperature freezing chamber,
Protects samples and meets low-temperature needs for Western Blot experiments, electrophoresis, and transfer membranes.

Unboxing and Installation

Remove the high-speed low-temperature tissue grinder from the packaging box and place it in a suitable location. Confirm that all components are complete.
Use the wrench provided in the accessories to remove the two fastening screws at the bottom of the instrument. (Before the first grinding operation, make sure to remove the fastening screws.)

image.png
Place the machine on a level and flat laboratory bench to prevent vibrations during operation.
Let it stand for 10 hours to ensure the coolant is in place. Connect the power supply (200-240V) and turn on the power switch at the back of the grinder.
Turn on the compressor cooling switch and wait for 10-15 minutes. Observe if the temperature in the grinding chamber reaches the set temperature.
6.If the temperature reaches the set temperature, install the adapter and nut correctly, then cover the top and start the machine.

Sample Preparation
The adapter can be used to grind 96 samples simultaneously in a 96-well plate. The adapter includes a base that can hold a 96-well plate, a top cover, and a locking nut.
Take the samples to be ground and place them in the grinding tubes. It is recommended to use no more than 100mg of sample. Add the corresponding extraction solution, ensuring that the total volume of the sample and extraction solution is within half of the overall volume. Add a few appropriately sized grinding beads. To ensure grinding efficiency and quality, for larger volume samples, it is recommended to cut them into smaller pieces using scissors.
Unscrew the locking nut and remove the top cover. Place the grinding tubes into the adapter, then attach the top cover and tighten the locking nut in a clockwise direction. (The placement of the tubes should follow the principles of symmetry and balance.)

Operation Steps
Plug the power cord of the grinder into a grounded 220V power outlet, and turn on the power switch at the back of the grinder.
After the startup interface is displayed, wait for about 5 seconds to enter the main operating interface.
Once the grinder is turned on, the cooling system starts running. Place the grinding tubes containing the samples, tighten the adapter, and cover the top of the grinder.
Set the operating frequency, time, and number of cycles. Click the "Temperature Selection" button to choose the temperature mode and set the desired temperature for the grinding chamber or the cooling platform.
Click the start button to begin the grinding process. The instrument will automatically stop once the timer reaches zero.

Equipment Maintenance
Perform the following routine maintenance after each use to ensure the reliable operation of the grinder.
Make sure to turn off the power and unplug the power cord before cleaning.
If solvents, salt water, acidic or alkaline solutions are spilled on the grinder, immediately wipe them clean with a damp cloth to avoid damaging the instrument.
Do not use high-pressure sterilization on any part of the grinder, including the adapter.
The components of the adapter should be cleaned after use. Use an appropriate cleaning agent, rinse with distilled water, and then wipe dry with a paper towel.
After using an appropriate cleaning agent, wipe the grinder clean with a soft cloth.
The following disinfectants and cleaning agents are recommended for cleaning the grinder and adapter:
a) Ordinary cleaning agent
b) Neutral detergent
c) 70% alcohol content 

 Equipment List

No.

Product Name

Model/Specification

Quantity

Remarks

1

Tissue Homogenizer

SWE-FP

1

2

Standard Hollow Adapter

2mL*24

1

Can process 24 samples at once

3

Beads Pen

SYM-04Z

1

Suitable for 2mL grinding tubes, zirconia beads 4mm

4

Beads Pen

SYM-04B

1

Suitable for 2mL grinding tubes, steel beads 4mm

5

Beads Pen

SYM-03B

1

Suitable for 2mL grinding tubes, steel beads 3mm

6

2mL Centrifuge Tube

1

Tube wall is thickened, material strength is higher, and there is no RNA enzyme.




Protein Extraction

Product Name

Grinding Beads

Frequency

Grinding Time

Pause Time

Cycle times

Recommended Extraction Solution

Plant Stems, Leaves

Stainless Steel Beads 3mm*3, 4mm*1

60Hz

60s

15s

3

Protein Extraction Solution

Heart, Liver, Spleen, Lungs, Kidneys, Brain of Mice and Rats

Stainless Steel Beads 3mm*2, 4mm*1

60Hz

30s

15s

2

Protein Extraction Solution

Stomach, Intestines, Muscles, Fat, Pancreas of Mice and Rats

Stainless Steel Beads 3mm*2, 4mm*1

60Hz

45s

15s

2

Protein Extraction Solution

Skin, Ears, Tail, Blood Vessels of Mice and Rats

Stainless Steel Beads 3mm*3, 4mm*2

70Hz

60s

20s

3

Protein Extraction Solution

Cartilage, Hair, Hard Bones of Mice and Rats

Stainless Steel Beads 3mm*4, 4mm*2

70Hz

90s

20s

3

Protein Extraction Solution

(This condition is for reference only, and can be adjusted at any time during the experiment according to the grinding effect.)

 RNA Extraction

Product Name

Grinding Beads

Frequency

Grinding Time

Pause Time

Cycle times

Recommended Extraction Solution

Plant Stems, Leaves

Zirconia Beads 3mm*3, 4mm*1

60Hz

60s

15s

3

RNA Extraction Solution

Heart, Liver, Spleen, Lungs, Kidneys, Brain of Mice and Rats

Zirconia Beads Beads 3mm*2, 4mm*1

60Hz

30s

15s

2

RNA Extraction Solution

Stomach, Intestines, Muscles, Fat, Pancreas of Mice and Rats

Zirconia Beads Beads 3mm*3, 4mm*2

60Hz

45s

15s

2

RNA Extraction Solution

Skin, Ears, Tail, Blood Vessels of Mice and Rats

Zirconia Beads Beads 3mm*4, 4mm*2

70Hz

60s

20s

3

<p style="margin:0p
: AO-03-SWE-FP
: 3 Produits
Hurry! only 3 items left in stock.

Use collapsible tabs for more detailed information that will help customers make a purchasing decision.

Ex: Shipping and return policies, size guides, and other common questions.

  • Paste the label on a flat surface on the package
  • Make sure that both 1D and 2D barcodes are clearly visible
  • Ensure that the label is smooth and isn’t creased or wrinkled
  • Check for any tears, dents, holes or scratches
  • Pack your product tightly, with the right size packaging
  • Ensure both barcodes are on a flat surface of the package