EasyStep Human PDL1(Programmed Cell Death Protein 1 Ligand 1) ELISA Kit
AO-06-ELK084ES-96T
| Cat.No | ELK084ES |
| Product Name | EasyStep Human PDL1(Programmed Cell Death Protein 1 Ligand 1) ELISA Kit |
| Reactivity | Human |
| Alternative Names | CD274; PDL1; B7-H; B7H1; PD-L1; PDCD1L1; PDCD1-LG1; Programed Death Ligand 1; PDCD1LG1; Programmed Cell Death Protein 1 Ligand 1 |
| Assay Type | Sandwich |
| Sensitivity | 1.23 pg/mL |
| Standard | 1000 pg/mL |
| Detection Range | 15.63-1000 pg/mL |
| Sample Type | Serum, plasma |
| Assay Length | 1.5h |
| Research Area | Signal transduction;Tumor immunity;Infection immunity;Immune molecule;Autoimmunity; |
| Test Principle | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PDL1, and the Human PDL1 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human PDL1. After TMB substrate solution is added, only those wells that contain Human PDL1 and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PDL1 in the samples is then determined by comparing the OD of the samples to the standard curve. |

Use collapsible tabs for more detailed information that will help customers make a purchasing decision.
Ex: Shipping and return policies, size guides, and other common questions.