Human IL-1β(Interleukin 1 Beta) ELISA Kit 96 Tests

Human IL-1β(Interleukin 1 Beta) ELISA Kit 96 Tests

Feiyuebio
AO-05-FY-FY-EH1444

Human IL-1β(Interleukin 1 Beta) ELISA Kit 96 Tests

Human IL-1β ELISA Kit 96 Tests.PDF

MSDS.pdf

check En Stock
Hurry! only 10 items left in stock.
469,00 €
HT
Quantité

Product Details
Product Name in English:
Human IL-1β(Interleukin 1 Beta) ELISA Kit
Species:
Human
Alternative Name:
catabolin; IL1 beta; IL-1 beta; IL-1; IL1B; IL-1b; IL1-BETA; IL-1F2; IL1F2IL-1 beta; interleukin 1, beta; interleukin-1 beta; preinterleukin 1 beta; pro-interleukin-1-beta; IL1β; IL1b
Uniport ID:
P01584
Assay Type:
Sandwich
Standard:
20pg/mL
Sensitivity:
0.18 pg/mL
Detection Range:
0.31-20pg/mL
Assay Time:
3.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to IL-1β. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to IL-1β. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain IL-1β, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of IL-1β in the samples is then determined by comparing the OD of the samples to the standard curve.
Technical Data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
20 2.337 2.353 2.345 2.284
10 1.543 1.552 1.548 1.49
5 0.912 0.915 0.914 0.859
2.5 0.429 0.43 0.43 0.376
1.25 0.25 0.251 0.251 0.197
0.63 0.15 0.15 0.15 0.097
0.31 0.103 0.104 0.104 0.05
0 0.053 0.053 0.053 0
Linear
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 92-104 88-96 85-94
Average (%) 96 92 88
1:4 Range (%) 93-99 88-96 92-103
Average (%) 94 92 94
1:8 Range (%) 87-98 90-101 81-92
Average (%) 95 90 91
1:16 Range (%) 82-93 93-102 80-87
Average (%) 92 94 80
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
Rate of recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 89-107 98
EDTA plasma (n=8) 87-99 93
Cell culture media (n=8) 80-90

84

Assay Procedures
: AO-05-FY-FY-EH1444
: 10 Produits
Hurry! only 10 items left in stock.

Use collapsible tabs for more detailed information that will help customers make a purchasing decision.

Ex: Shipping and return policies, size guides, and other common questions.

  • Paste the label on a flat surface on the package
  • Make sure that both 1D and 2D barcodes are clearly visible
  • Ensure that the label is smooth and isn’t creased or wrinkled
  • Check for any tears, dents, holes or scratches
  • Pack your product tightly, with the right size packaging
  • Ensure both barcodes are on a flat surface of the package