Product Information
Product Name |
Cat. No. |
Spec. |
Gel Casting System Solution Set |
AO-03-G2180-2L |
500 mL ×4 |
Product Description/Introduction
This set together with Gel casting system,provide a convinient method for electrophoresis gel proparation.Users only to insert the aspiration tubes A\B\C in corresponding reagent bottles respectively.then follow the program of the casting system to get the correspond gel of Tris-HCl system.Compared with the traditional gel preparation method, it has the following advantages:
Easy to use:No caculating,no hand making,just click the desired concentration to get the gel.
No TEMED No bad ordor:There is no need to add TEMED in the gel proparationprocess, avoiding exposure to foul-smelling toxic reagents.
Excellent separation effect:this set together with gel casting program.Both isocratic and gradient gels can be prepared by this system.
Storage and Shipping Conditions
Ship with wet ice; solution A and B need to be stored at room temprature to avoid light.Please store at 4℃ if not used for a long time, valid for 12 months.Solution C store at room temperature for 1 month,2-8°C for 3 month.Please store at -20℃ if not used for a long time,validfor 12 months.
Product Features
1.This reagent kit is designed for use with the Servicebio Gel Casting System T-20.
2.It can prepare gradient gels and isocratic gels of various concentrations ranging from 4% to 20%.
3.The instrument is easy to set up, with real-time mixing of reagents to prevent premature solidification, allowing for continuous gel production.
4.The accompanying reagent kit can continuously produce approximately 260 gels, with each gel costing less than 1 €/pc.
Component
Component number |
Component |
AO-03-G2180-2L |
G2180-1 |
Gel Casting System Solution A |
500 mL |
G2180-2 |
Gel Casting System Solution B |
500 mL |
G2180-3 |
Gel Casting System Solution C |
500 mL×2 |
Manual |
1 pcs |
Procedure
1.Place solution A, B and C in the corresponding slots on the dispenser and determine the height of the liquid level.
2.insert the aspiration tubes A\B\C in corresponding reagent bottles respectively(red tube to solution A, green tube to solution B, yellow tube to solution C).
3.Run the corresponding program of the dispenser to see the reagents being pumped into the corresponding pipeline.
Note
1.Be sure to match solution A, B and C with the right tubes.(red tube to solution A, green tube to solution B, yellow tube to solution C).
2.Do not mix solution A/B/C,it may cause the reagent to coagulate。
3.Regularly check the height of the liquid level,If there are any deficiencies, add them in time。
For Research Use Only!
Use collapsible tabs for more detailed information that will help customers make a purchasing decision.
Ex: Shipping and return policies, size guides, and other common questions.
- Paste the label on a flat surface on the package
- Make sure that both 1D and 2D barcodes are clearly visible
- Ensure that the label is smooth and isn’t creased or wrinkled
- Check for any tears, dents, holes or scratches
- Pack your product tightly, with the right size packaging
- Ensure both barcodes are on a flat surface of the package